Tilt-and-turn
PVC, Uw 0.79 W/m²K
Est. 1998 Window systems, Winterthur
We fabricate six-chamber PVC and thermally broken aluminum units to your drawings, down to Uw 0.76 W/m²K. Triple glazing is standard, and the crew that builds each unit also fits and seals it.
Fig. 01 Two-light tilt-and-turn, 120 mm system depth, elevation at 1:20.
A frame is only as good as its section. We work from our own profiles so the thermal break, the glazing rebate and the seals line up on every unit, not just the first one.
Three profile families cover most openings. Each unit is welded, glazed and pressure-tested at the bench before it leaves the workshop, and every specification below is a value we build to, not a range we hope to hit.
| System | Construction | Uf | Sightline | Typical use |
|---|---|---|---|---|
| PVC | Six chambers, galvanised steel core, welded corners, co-extruded seals. | 1.0 W/m²K | 70 mm | Houses, flats, renovations |
| Aluminum | Thermally broken with polyamide bridges, powder-coated to RAL or anodised. | 1.4 W/m²K | 62 mm | Wide spans, storefronts, load cases |
| Composite | Aluminum-clad PVC: PVC core for thermal, aluminum shell for weather and colour. | 1.1 W/m²K | 68 mm | Coastal and exposed facades |
A surveyor checks every opening before fabrication starts, so each unit arrives sized for the wall it fills. The same crew sets, shims, insulates and seals it, then tests the hardware. One contract, one point of contact.
Standard types below, all built to order. Send a dimension sketch and we confirm the profile, glazing and hardware for your opening before we price it.
Tilt-and-turn
PVC, Uw 0.79 W/m²K
Entrance door
Aluminum, flush threshold
Sliding patio
Lift-and-slide, 2.4 m leaf
Tested to EN 14351-1 and documented per unit. Certificates for thermal, wind load and water tightness ship with every order.
28
Years fabricating windows and doors
12k
Units built each year
0.76W/m²K
Best Uw across the range
14
Countries served from Winterthur
| Property | Value | Test standard |
|---|---|---|
| Thermal transmittance | 0.76–1.10 W/m²K | EN ISO 10077-1 |
| Frame transmittance | 1.0–1.4 W/m²K | EN ISO 10077-1 |
| Air permeability | Class 4 | EN 12207 |
| Wind load | C4, 2000 Pa | EN 12210 |
| Water tightness | E1200 | EN 12208 |
| Sound reduction | 33–45 dB | EN ISO 717-1 |
Send dimensions, drawings or a hand sketch. We reply with a fixed quote, a confirmed profile and a lead time within one business day.